What the module models
When a local pressure disturbance collapses the vapor film separating molten droplets from liquid water, millimetre-scale droplets fragment into sub-millimetre particles within fractions of a millisecond. The resulting jump in interfacial area transfers thermal energy rapidly into the surrounding coolant, driving a self-sustained high-pressure wave through the premixture. In SEINA-3D v1, this module models local triggering, pressure-wave-driven fine fragmentation, rapid heat release, and the resulting wall overpressure and pressure impulse distributions.
Governing equations
External triggering is prescribed as a localized high-pressure vapor pocket in the trigger zone at . As the compression wave sweeps across coarse melt droplets () where liquid melt remains available, the mass transfer rate per unit mixture volume into the fine-fragment field () follows the Tang pressure-driven fine-fragmentation correlation:
Here is the fine-fragmentation coefficient, is the threshold pressure required to destabilize the vapor film, is the local coarse-droplet diameter, is the surrounding coolant density, and accounts for local void-fraction suppression as vapor cushions direct liquid–melt impact at high void fractions.
Newly generated fine fragments () provide high specific surface area , driving intense heat transfer into the coolant and rapid interfacial vaporization behind the shock front. Dynamic wall loads at axial and azimuthal sensor stations are quantified by peak overpressure above initial pressure and pressure impulse integrated over :
Numerical method
Explosion calculations use compressible IAPWS-IF97 liquid and vapor equations of state within the multiphase SIMPLEPC solver, resolving the dramatic drop in two-phase acoustic speed across void-fraction gradients. Time steps are restricted to sub-microsecond to microsecond intervals so shock propagation, mass conversion, and fine-fragment quenching remain tightly coupled across three-dimensional cylindrical or Cartesian vessel meshes.
Verification
Three-dimensional explosion propagation and dynamic wall-load characteristics were investigated in the accepted study of Sun et al. using the vessel geometry (, water column height ) and alumina–water thermodynamic reference conditions of KROTOS K42 across premixing and trigger configurations:
- Reference wave propagation: in the baseline configuration, self-sustained fine fragmentation behind the upward-propagating pressure front produced a peak overpressure of at wall station K2 and a pressure impulse of over .
- Premixing state coupling: parametric calculations quantified how lower void fraction and smaller droplet diameter jointly raise peak overpressure by accelerating and strengthening liquid-phase confinement.
- Trigger elevation and three-dimensional off-axis effects: shifting the axial trigger height redistributed pressure impulse across wall sensors K1–K5, while displacing the premixed melt column off the vessel axis produced pronounced azimuthal variation in wall peak overpressure around the tube circumference.