What the module models
As a high-temperature melt jet penetrates a water pool, shear along the jet column strips off coarse droplets, hydrodynamic forces break liquid droplets into smaller sizes until surface solidification arrests deformation, and film boiling together with thermal radiation generates a rising vapor envelope. In SEINA-3D v1, this module supplies the interfield mass, interfacial area, and thermal exchange rates connecting the melt fields with liquid water and steam during premixing.
Governing equations
Connected-jet stripping and leading-edge breakup criterion
Along the lateral surface of the connected melt jet inside a control volume , shear stripping transfers melt mass and creates coarse-droplet interfacial area concentration at rates:
where is the initial stripped droplet diameter and the entrainment velocity takes in bubbly and transition regimes and in vapor-dominated droplet and jet regimes.
To determine the jet breakup length consistently in three-dimensional transient simulations, SEINA-3D v1 identifies the melt region connected to the inlet across six-neighbour cell faces together with piecewise linear interface calculation (PLIC) front reconstruction. The normalized leading-edge speed is sampled at dimensionless time intervals of and fitted over a five-point window of width ; breakup is identified at the onset of sustained tip deceleration where the slope magnitude stays below across three consecutive intervals.
Hydrodynamic droplet fragmentation and solid-crust arrest
Coarse melt droplets subject to relative velocity undergo Pilch–Erdman hydrodynamic fragmentation once the Weber number exceeds :
When radiative and boiling heat losses form a solidified outer shell of thickness , elastic bending resistance restrains deformation. Fragmentation then requires the modified aeroelastic number (with shell elastic modulus and Poisson ratio ) to exceed the critical threshold:
Boiling, radiative heat transfer, and interfacial phase change
Convective and film-boiling heat transfer between dispersed melt and coolant phase follows . Thermal radiation across the vapor film is evaluated from a two-surface grey-body formulation weighted by local liquid fraction :
Accounting for spectral absorption in water, of is deposited into the liquid bulk and acts directly at the vapor–liquid interface. Net heat reaching the saturation interface determines the evaporation or condensation mass source :
Numerical method
Interfacial area concentration is advected alongside phase volume fraction so local Sauter mean diameter tracks stripping and secondary breakup continuously across cells. Heat-transfer coefficients, crust growth, and phase-change rates are updated inside the outer pressure-correction loop at each time step, preventing explicit thermal overshoot when local void fraction changes rapidly around the melt jet.
Verification
- KTH melt-jet breakup tests: validated across six jet breakup experiments (, ) in Sun et al. (2026), achieving a mean absolute relative difference of in dimensionless breakup length and capturing how coolant subcooling modifies the velocity dependence of .
- FARO L-24 prototypic corium–water experiment: validated in Sun et al. (2027) for of melt at pouring into of water at and on a medium grid. In the steam-only calculation, predicted vessel pressure peaked at compared with in the experiment (root-mean-square error of across comparison times), and the reconstructed median fragment size closely matched the measured .